Improvement in male pelvis magnetic resonance image contouring following radiologist-delivered training

Oar, Bronwyn, Brown, Amy, Newman, Glen, Boles, Alan, Rumley, Christopher N., Doyle, Rachel, Baines, John, and Tan, Alex (2024) Improvement in male pelvis magnetic resonance image contouring following radiologist-delivered training. Journal of Medical Radiation Sciences, 71 (1). pp. 114-122.

[img]
Preview
PDF (Accepted Publisher Version) - Accepted Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (705kB) | Preview
View at Publisher Website: https://doi.org/10.1002/jmrs.727
 
39


Abstract

Introduction: The magnetic resonance linear accelerator (MRL) combines both magnetic resonance imaging and a linear accelerator, allowing for daily treatment adaptation. This study aimed to assess the impact of radiologist-delivered training in magnetic resonance (MR) contouring of relevant structures within the male pelvis.

Methods: Two radiation oncologists, two radiation oncology registrars and seven radiation therapists completed contouring on 10 male pelvis MR datasets both pre- and post-training. A 2-hour MR anatomy training session was delivered by a radiologist, who also provided the ‘gold standard’ contours. The pre- and post-training contours were compared against the gold standard with Dice similarity coefficient (DSC) and Hausdorff distances calculated; and the pre- and post-confidence scores and timing were compared.

Results: The improvement in DSC were significant in prostate, rectum and seminal vesicles, with a post-training median DSC of 0.87 ± 0.06, 0.92 ± 0.04 and 0.80 ± 0.14, respectively. The median Hausdorff improved with a median of 1.46 ± 0.78 mm, 0.52 ± 0.32 mm and 1.11 ± 0.86 mm for prostate, rectum and seminal vesicles, respectively. Bladder concordance was high both pre- and post-training. Urethra contours improved post-training, however, remained difficult to contour with a median post-DSC of 0.51 ± 0.24. Overall, confidence scoring improved (P < 0.001) and timing decreased by an average of 4.4 ± 16.4 min post-training.

Conclusion: Radiologist-delivered training improved concordance of male pelvis contouring on MR datasets. Further work is required in the identification of urethra on MRs. These findings are of importance in the MRL adaptive workflow.

Item ID: 80921
Item Type: Article (Research - C1)
ISSN: 2051-3909
Keywords: magnetic resonance imaging, magnetic resonance linear accelerator, planning, radiation oncology
Copyright Information: © 2023 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
Date Deposited: 14 Feb 2024 02:31
FoR Codes: 32 BIOMEDICAL AND CLINICAL SCIENCES > 3202 Clinical sciences > 320222 Radiology and organ imaging @ 100%
SEO Codes: 28 EXPANDING KNOWLEDGE > 2801 Expanding knowledge > 280103 Expanding knowledge in the biomedical and clinical sciences @ 100%
Downloads: Total: 39
Last 12 Months: 8
More Statistics

Actions (Repository Staff Only)

Item Control Page Item Control Page