Predictive Accuracy of Wideband Absorbance under Various Pressure Conditions in Identifying Infants with a Conductive Hearing Loss
Aithal, Sreedevi, Aithal, Venkatesh, Kei, Joseph, and Wilson, Matthew (2024) Predictive Accuracy of Wideband Absorbance under Various Pressure Conditions in Identifying Infants with a Conductive Hearing Loss. Journal of the American Academy of Audiology, 35 (07/08). pp. 193-203.
![]() |
PDF (Published Version)
- Published Version
Restricted to Repository staff only |
Abstract
Objective The objectives of the study were to (i) evaluate the effectiveness of wideband absorbance (WBA) at ambient pressure (WBAamb), tympanic peak pressure (WBATPP), and 0 daPa (WBA0) to identify conductive hearing loss (CHL) in infants and (ii) compare the sensitivity and specificity of the three WBA tests with that of high-frequency tympanometry (HFT) and transient-evoked otoacoustic emissions (TEOAE).
Method A total of 31 ears with hearing thresholds no greater than 20 dB HL (reference group from 20 infants [mean age: 3.1 weeks]) and 47 ears with CHL from 31 infants (mean age: 3.4 weeks) were included in the study. Hearing threshold was determined using air-conduction tone-burst auditory brainstem response (TB-ABR) test, whereas CHL was determined using both air- and bone-conduction TB-ABR tests. HFT with a 1000-Hz probe tone, TEOAE, and WBA tests were conducted on all participants.
Results WBAamb, WBATPP, and WBA0 of the CHL group were significantly lower than that of the reference group across a wide frequency range. Area under the receiver operating characteristic (AROC) curve for detecting CHL varied from 0.51 to 0.9 depending on the frequency. The highest AROC was obtained at 1.25 kHz for WBAamb (0.79), at 1.5 kHz for WBATPP (0.9) and at 1 kHz for WBA0 (0.80). The sensitivity and specificity were 0.98 and 0.45, respectively for HFT, and 1.0 and 0.6, respectively for TEOAE. In comparison, the WBA test had slightly lower sensitivity but higher specificity than the HFT and TEOAE tests.
Conclusion WBATPP at 1.5 kHz can identify CHL in infants as good as, if not more accurately than, WBAamb or WBA0. WBATPP test had good balance of high sensitivity and specificity compared with HFT and TEOAE. The three WBA tests are useful tools for identifying CHL in infants under 6 weeks of age.
Item ID: | 84851 |
---|---|
Item Type: | Article (Research - C1) |
ISSN: | 2157-3107 |
Copyright Information: | © 2024. American Academy of Audiology. All rights reserved. Thieme Medical Publishers. |
Date Deposited: | 11 Mar 2025 22:54 |
FoR Codes: | 42 HEALTH SCIENCES > 4201 Allied health and rehabilitation science > 420102 Audiology @ 60% 42 HEALTH SCIENCES > 4201 Allied health and rehabilitation science > 420110 Speech pathology @ 40% |
SEO Codes: | 20 HEALTH > 2003 Provision of health and support services > 200301 Allied health therapies (excl. mental health services) @ 70% 20 HEALTH > 2005 Specific population health (excl. Indigenous health) > 200506 Neonatal and child health @ 30% |
Downloads: |
Total: 1 Last 12 Months: 1 |
More Statistics |