Mismatch between trochlear coronal alignment of arthritic knees and currently available prosthesis: a morphological analysis of 4116 knees and 45 implant designs

Rosa, Sergio Barroso, Hazratwala, Kaushik, and Wilkinson, Matthew P.R. (2023) Mismatch between trochlear coronal alignment of arthritic knees and currently available prosthesis: a morphological analysis of 4116 knees and 45 implant designs. Knee Surgery, Sports Traumatology, Arthroscopy, 31. pp. 3116-3123.

[img]
Preview
PDF (Published Version) - Published Version
Available under License Creative Commons Attribution.

Download (951kB) | Preview
View at Publisher Website: https://doi.org/10.1007/s00167-022-07251...
 
3
197


Abstract

Purpose: In up to a fifth of total knee replacements (TKR), surgeons are not capable of achieving good clinical and functional results. Despite comprehensive diagnostic workup, an underlying cause is not always identified in these patients. The purpose of this study is to compare native and prosthetic trochlear anatomies, to evaluate a potential source of morphologic mismatch and theoretically, of poor clinical outcomes.

Methods: Native trochlear angles of 4116 knee CTs from 360 Knee Systems database of arthritic pre-operative TKR patients were evaluated. A semi-automated tridimensional analysis was performed to define the native trochlear angle in the coronal plane (NTA) among other 142 parameters. An active search was conducted to identify currently available TKR models; prosthetic trochlear orientation in the coronal plane (PTA) was extracted from the technical data provided by manufacturers.

Results: The mean native trochlear angle (NTA) was 1.6° ± 6.6° (valgus) with a range from − 23.8° (varus) to 30.3°(valgus). A valgus NTA was present in 60.6% of the knees and 39.4% of them had a varus NTA. 89 TKR models were identified; trochlear details were available for 45 of them, of which 93% were designed with a valgus orientation of the prosthetic trochlear angle (PTA) and 6.9% showed a neutral (0°) PTA. Varus alignment of PTA was not present in any system. Angular numeric values for PTA were available for 34 models; these ranged from 0° to 15° of valgus, with a median value of 6.18° (SD ± 2.88°).

Conclusion: This study shows a significant mismatch between native and prosthetic trochlear angles. A relevant proportion of the studied knees (41.45%) fall out of the trochlear angle range of currently available implants; representing a potential source for biomechanical imbalance. While further research is warranted to fully understand the clinical implications of the present study, manufacturers may need to take these findings into account for future implant designs.

Level of evidence: Level III, retrospective cohort study.

Item ID: 77676
Item Type: Article (Research - C1)
ISSN: 1433-7347
Keywords: Osteoarthritis, Patellofemoral joint, Prosthesis design, Total knee replacement
Copyright Information: © The Author(s) 2022. This article is licensed under a Creative Commons Attribution 4.0 International License.
Date Deposited: 06 Oct 2023 03:06
FoR Codes: 32 BIOMEDICAL AND CLINICAL SCIENCES > 3202 Clinical sciences > 320216 Orthopaedics @ 50%
32 BIOMEDICAL AND CLINICAL SCIENCES > 3202 Clinical sciences > 320226 Surgery @ 50%
SEO Codes: 20 HEALTH > 2001 Clinical health > 200105 Treatment of human diseases and conditions @ 100%
Downloads: Total: 197
Last 12 Months: 93
More Statistics

Actions (Repository Staff Only)

Item Control Page Item Control Page