Primary prevention implantable cardiac defibrillators: a Townsville district perspective

Engstrom, Nathan, Dobson, Geoffrey, Ng, Kevin, and Letson, Hayley (2020) Primary prevention implantable cardiac defibrillators: a Townsville district perspective. Frontiers in Cardiovascular Medicine, 7. 577248.

[img]
Preview
PDF (Published Version) - Published Version
Available under License Creative Commons Attribution.

Download (380kB) | Preview
View at Publisher Website: https://doi.org/10.3389/fcvm.2020.577248
 
4
869


Abstract

Background: Despite major advances in treating patients with severe heart failure, deciding who should receive an implantable cardiac defibrillator (ICD) remains challenging.

Objective: To study the risk factors and mortality in patients after receiving an ICD (January 2008–December 2015) in a regional hospital in Australia.

Methods: Eighty-two primary prevention patients received an ICD for ischemic cardiomyopathy (ICM, n = 41) and non-ischemic cardiomyopathy (NICM, n = 40) with 4.8-yrs follow-up. One patient had mixed ICM/NICM indications. Ventricular arrhythmias were assessed using intracardiac electrograms. Statistical analysis compared the total population and ICM and NICM groups using Kaplan-Meier for survival, Cox regression for mortality predictors, and binary logistic regression for predictors of ventricular arrhythmias (p < 0.05).

Results: Major risk factors were hypercholesterolemia (70.7%), hypertension (47.6%), and obesity (41.5%). Severe obstructive sleep apnea (OSA) was found exclusively in NICM patients (23.7%, p = 0.001). Mortality was 30.5% after 4.8-yrs. The majority of patients (n=67) had no sustained ventricular arrhythmias yet 28% received therapy (n = 23), 18.51% were appropriate (n = 15), and 13.9% inappropriate (n = 11). Patients receiving ≥2 incidences of inappropriate shocks were 18-times more likely to die (p =0.013). Three sudden cardiac deaths (SCD) (3.7%) were prevented by the ICD.

Conclusion: Patients implanted with an ICD in Townsville had 30.5% all-cause mortality after 4.8-yrs. Only 28% of patients received ICD therapy and 13.9% were inappropriate. OSA may have contributed to the fourfold increase in inappropriate therapy in NICM patients. Our study raises important efficacy, ethical and healthcare cost questions about who should receive an ICD, and possible regional and urban center disparities.

Item ID: 64871
Item Type: Article (Research - C1)
ISSN: 2297-055X
Keywords: defibrillator, primary prevention, arrhythmia, sudden cardiac death, shocks
Copyright Information: © 2020 Engstrom, Dobson, Ng and Letson. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice.No use, distribution or reproduction is permitted which does not comply with these terms
Date Deposited: 10 Nov 2020 19:19
FoR Codes: 32 BIOMEDICAL AND CLINICAL SCIENCES > 3201 Cardiovascular medicine and haematology > 320101 Cardiology (incl. cardiovascular diseases) @ 100%
SEO Codes: 92 HEALTH > 9201 Clinical Health (Organs, Diseases and Abnormal Conditions) > 920103 Cardiovascular System and Diseases @ 100%
Downloads: Total: 869
Last 12 Months: 3
More Statistics

Actions (Repository Staff Only)

Item Control Page Item Control Page