Development of a full-scale structural testing program to evaluate the resistance of Australian houses to wind loads.

Boughton, Geoffrey Neville, Parackal, Korah, Satheeskumar, Navaratnam, and Henderson, David James (2017) Development of a full-scale structural testing program to evaluate the resistance of Australian houses to wind loads. Frontiers in Built Environment, 3. 21.

[img]
Preview
PDF (Published Version) - Published Version
Available under License Creative Commons Attribution.

Download (3MB) | Preview
View at Publisher Website: http://dx.doi.org/10.3389/fbuil.2017.000...
 
210


Abstract

Extensive damage to houses during severe tropical cyclones in the 1970s in Australia highlighted the need for research-based structural engineering principles to be applied in design and construction of houses. Houses have structural redundancies and complex load paths, so the analysis of even simple houses was complicated. In order to evaluate the structural performance of these parallel systems, full-scale house testing commenced at the Cyclone Testing Station (CTS) in the early 1980s with the static multipoint loading of an old house destined for demolition. Following that test program, nine full-scale houses were tested under static and cyclic loading to evaluate load paths in different types of houses with different building practices and materials. Results have been incorporated into amendments of house construction codes, standards, and manuals. Advances in computer modeling and instrumentation have led to more sophisticated full-scale studies. Data on real houses under construction have informed this work and enabled analytical models to incorporate variability in strength of connections in a way that a single test cannot. Progressive failure in the structural systems of timber-framed housing can now be studied to differentiate between houses that have significant damage and seemingly identical ones that have limited damage in the same wind event. These studies involve wind tunnel investigations to determine temporal pressure distributions; full-scale multiple tests on connections (with and without construction defects) to determine statistical distributions of strength and load/deflection relationships; and full-scale tests on houses or portions of houses to determine load sharing mechanisms between parallel structural and non-structural elements. The results of the test programs were used to calibrate the analytical models, which can be used for reliability studies. The paper presents a summary of the methodology and findings from previous CTS full-scale house tests. The results of the most recent research using full-scale tests on a portion of a house and its companion numerical models are discussed and the benefits and limitations of the process outlined.

Item ID: 52850
Item Type: Article (Research - C1)
ISSN: 2297-3362
Keywords: cyclone, full-scale, testing, wind, house, model, failure
Additional Information:

This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

Date Deposited: 09 Mar 2018 00:29
FoR Codes: 40 ENGINEERING > 4005 Civil engineering > 400510 Structural engineering @ 100%
SEO Codes: 87 CONSTRUCTION > 8702 Construction Design > 870204 Residential Construction Design @ 50%