The anatomical position of three extraglottic airway devices in patients with clear airways

van Zundert, A., Brimacombe, J., Kamphius, R., and Haanschoten, M. (2006) The anatomical position of three extraglottic airway devices in patients with clear airways. Anaesthesia, 61 (9). pp. 891-895.

[img] PDF (Published Version) - Published Version
Restricted to Repository staff only

View at Publisher Website: http://dx.doi.org/10.1111/j.1365-2044.20...
 
18
3


Abstract

We tested the hypothesis that, in patients with clear airways, the anatomical position of three single-use extraglottic airway devices is similar. The airways studied were: the laryngeal mask airway unique (LMA-U™), the Softseal laryngeal mask airway (SS-LM™) and the Cobra perilaryngeal airway (Cobra-PLA™). Three hundred spontaneously breathing patients were randomly allocated to have their airway managed using one of these three supraglottic airway devices. A rigid endoscope was passed down the airway tube and the following anatomical assessments were made: position of the epiglottis; position of the glottis; and position of the cuff. The epiglottis was more frequently visible with the LMA-U than with the SS-LM (76 vs 57%, p = 0.006) and with the LMA-U than with the Cobra-PLA (76 vs 46%, p < 0.0001). The epiglottis was in contact with the mask aperture bars in 25% of patients, and in 34% of these, the epiglottis was seen to be herniated through the aperture bars. Herniation of the epiglottis through the mask aperture bars occurred more frequently with the Cobra-PLA than the LMA-U (8 vs 3%, p = 0.008). The vocal cords and arytenoids were more frequently visible with the LMA-U and SS-LM than with the Cobra-PLA (both p < 0.006). Herniation of the arytenoids through the mask aperture bars was more frequently seen with the Cobra-PLA than with the LMA-U (8 vs 0%, p = 0.004). The position of the cuff was optimal for the LMA-U and SS-LM in 90% and 93% of patients, respectively. The cuff was more frequently in the midline with the LMA-U than with the SS-LM (p = 0.002). We conclude that the anatomical position of the LMA-U and SS-LMA is superior to that of the Cobra-PLA in patients with clear airways. The mask aperture bars probably have no anatomical utility and predispose to herniation of the pharyngeal structures.

Item ID: 3758
Item Type: Article (Research - C1)
ISSN: 1365-2044
Keywords: airways; anatomical position; laryngeal mask; Cobra-PLA
Date Deposited: 26 Nov 2009 05:30
FoR Codes: 11 MEDICAL AND HEALTH SCIENCES > 1116 Medical Physiology > 111699 Medical Physiology not elsewhere classified @ 50%
11 MEDICAL AND HEALTH SCIENCES > 1103 Clinical Sciences > 110301 Anaesthesiology @ 50%
SEO Codes: 92 HEALTH > 9201 Clinical Health (Organs, Diseases and Abnormal Conditions) > 920115 Respiratory System and Diseases (incl. Asthma) @ 51%
92 HEALTH > 9299 Other Health > 929999 Health not elsewhere classified @ 49%
Downloads: Total: 3
More Statistics

Actions (Repository Staff Only)

Item Control Page Item Control Page