The in vivo anatomy of the deep circumflex iliac artery perforators: defining the role for the DCIA perforator flap

Ting, Jeanette W.C., Rozen, Warren M., Grinsell, Damien, Stella, Damien L., and Ashton, Mark W. (2009) The in vivo anatomy of the deep circumflex iliac artery perforators: defining the role for the DCIA perforator flap. Microsurgery, 29 (4). pp. 326-329.

[img] PDF (Published Version) - Published Version
Restricted to Repository staff only

View at Publisher Website: http://dx.doi.org/10.1002/micr.20633
 
24
1


Abstract

The deep circumflex iliac artery (DCIA) provides a dependable option for use as an osteo-musculo-cutaneous flap, particularly in mandibular reconstruction. Modifications to flaps based on DCIA perforators have been sought to prevent donor site morbidity as a consequence of muscle cuff harvest. Previous studies have been inconsistent in their descriptions of perforator anatomy, and means of assessing these preoperatively have not been widely described. A clinical anatomical study was undertaken, with a cohort of 44 hemiabdominal walls in 22 consecutive patients undergoing preoperative computed tomographic angiography (CTA) before free flap surgery. The feasibility of CTA and the regional vascular anatomy were both assessed. The use of CTA was shown to demonstrate DCIA perforators with high resolution and to be able to assess vessel size and location. In 44 hemiabdominal walls, there were 44 perforators of >0.8 mm diameter. There were no suitable perforators in 40% of sides, with 32% of sides having one perforator >0.8 mm diameter, 16% having two perforators, <10% had three perforators, and only one side had over four perforators. Perforators emerged from the deep fascia on an average of 5.1 cm cranial and 3.9 cm posterior to the anterior superior iliac spine (ASIS). Of the 44 perforators identified, 82% of perforators were located within a 4 cm by 4 cm area, 3 cm superior, and 2 cm posterior to the ASIS. The current study has demonstrated the utility of preoperative CTA for identifying DCIA perforators, and for selecting patients who may be suitable for a DCIA perforator flap given the variable perforator anatomy.

Item ID: 32413
Item Type: Article (Research - C1)
ISSN: 1098-2752
Date Deposited: 29 Apr 2014 01:06
FoR Codes: 11 MEDICAL AND HEALTH SCIENCES > 1103 Clinical Sciences > 110320 Radiology and Organ Imaging @ 50%
11 MEDICAL AND HEALTH SCIENCES > 1103 Clinical Sciences > 110323 Surgery @ 50%
SEO Codes: 92 HEALTH > 9201 Clinical Health (Organs, Diseases and Abnormal Conditions) > 920118 Surgical Methods and Procedures @ 40%
92 HEALTH > 9202 Health and Support Services > 920203 Diagnostic Methods @ 40%
97 EXPANDING KNOWLEDGE > 970111 Expanding Knowledge in the Medical and Health Sciences @ 20%
Downloads: Total: 1
More Statistics

Actions (Repository Staff Only)

Item Control Page Item Control Page