Similar oropharyngeal leak pressures during anaesthesia with i-gel™, LMA-ProSeal™ and LMA-Supreme™ Laryngeal Masks

van Zundert, T.C.R.V., and Brimacombe, J.R. (2012) Similar oropharyngeal leak pressures during anaesthesia with i-gel™, LMA-ProSeal™ and LMA-Supreme™ Laryngeal Masks. Acta Anaesthesiologica Belgica, 63 (1). pp. 35-41.

[img] PDF (Published Version) - Published Version
Restricted to Repository staff only

 
31
7


Abstract

Introduction: We test the hypothesis that there are differences in performance among three extraglottic airway devices during spontaneous breathing anaesthesia.

Methods: One hundred and fifty consecutive patients (ASA Grade 1-2, aged 18-80 yr) were randomly allocated for airway management with the i-gel® (Intersurgical Ltd, Wokingham, Berkshire UK), the LMA-ProSeal® and the LMA-Supreme® (The Laryngeal Mask Company Ltd, Wooburn Green, Bucks, UK). Anaesthesia was with fentanyl/propofol/sevoflurane mixture. A laryngoscope-guided, gastric tube-guided technique was used for insertion.

The following primary variables were assessed: ease of insertion, effective airway time, anatomical position, oropharyngeal leak pressure among devices, and change in oropharyngeal leak pressure between 30 and 60 minutes for each device during the spontaneous breathing anaesthesia.

Results: Differences detected were that the LMA-Supreme was easier to insert and had a shorter effective airway time than the LMA-Proseal and i-gel. Anatomical position was better for the LMA-Supreme than for the i-gel. Oropharyngeal leak pressures were similar among devices during apnoea and spontaneous ventilation, but much higher than in the first generation classic type of laryngeal masks. There were no changes in oropharyngeal leak pressure for any device during the spontaneous breathing phase. There were no differences in performance for any variable between the LMA-ProSeal and i-gel.

Conclusion: The LMA-Supreme is easier and quicker to insert than the LMA-ProSeal and i-gel using a laryngoscope-guided, gastric tube-guided technique and is associated with better anatomical positioning than the i-gel. Oropharyngeal leak pressures are similar among devices. © Acta Anæsthesiologica Belgica, 2012.

Item ID: 25343
Item Type: Article (Research - C1)
ISSN: 0001-5164
Keywords: anesthesia; ease of insertion; effective airway time; laryngeal mask airways; oropharyngeal leak pressure
Date Deposited: 11 Mar 2013 00:28
FoR Codes: 11 MEDICAL AND HEALTH SCIENCES > 1103 Clinical Sciences > 110301 Anaesthesiology @ 100%
SEO Codes: 92 HEALTH > 9201 Clinical Health (Organs, Diseases and Abnormal Conditions) > 920118 Surgical Methods and Procedures @ 100%