Study of tractional force for various pelvic reconstructive graft materials - an experimental animal model

Kannan, K., Watt, K., Fiadjoe, P., and Rane, A. (2010) Study of tractional force for various pelvic reconstructive graft materials - an experimental animal model. International Urogynecology Journal, 21 (S1). 196. pp. 282-284.

[img] PDF (Published Version) - Published Version
Restricted to Repository staff only

 
1


Abstract

[Extract] Hypothesis / aims of study: To compare tensile strengths of three different types of mesh used in pelvic reconstruction surgery at different stages of healing and evaluate the extent of tissue integration at each stage.

Study design, materials and methods: Forty five female Wistar rats were subcutaneously implanted with one of three types of mesh, elastic low density monofilament polypropylene mesh (high friction arm of MonarcTM suburethral sling), soft monofilament polypropylene mesh (PerigeeTM, AMS), and SIS porcine mesh (Surgisis, Cook Medical). Tensile strength was tested at days 10, 19, 25, 33 and 40 by mobilising the meshes using a dynamometer. The meshes and overlying tissue were histologically examined for tissue integration using the parameters inflammatory response, degree of fibrous tissue formation and collagen deposition.

Results; We found an essentially linear increase in tensile strength over 40 days in both polypropylene meshes, the highest being an average of 19.385 N at Day 40. The high friction arm mesh had higher tensile strength at Days 19 and 25 of the study compared to the soft section of polypropylene mesh. There was no appreciable difference between the two at Day 40. There was a significantly lower tensile strength in the SIS mesh across all stages of healing, with no increase in strength over time. This mesh from Day 25 onwards was unable to be separated in one piece from the tissue.

Concluding message: The high friction arm of the MonarcTM mesh had higher tensile strength earlier then the soft polypropylene mesh of PerigeeTM. But there was no difference in both meshes by day 40 and both had higher tensile strengths than the SIS. The SIS mesh separation point was within the mesh, rather than between the mesh-tissue interfaces, suggesting stronger tissue integration than internal mesh strength.

Item ID: 14989
Item Type: Article (Abstract)
ISSN: 1433-3023
Related URLs:
Date Deposited: 24 Nov 2010 01:34
FoR Codes: 11 MEDICAL AND HEALTH SCIENCES > 1114 Paediatrics and Reproductive Medicine > 111402 Obstetrics and Gynaecology @ 100%
SEO Codes: 92 HEALTH > 9201 Clinical Health (Organs, Diseases and Abnormal Conditions) > 920118 Surgical Methods and Procedures @ 100%
Downloads: Total: 1
More Statistics

Actions (Repository Staff Only)

Item Control Page Item Control Page